Publication #1200-01 Firmware Version: V3.919 08/01/14
SyringePump.com
Model: NE-1000
Multi-Phaser™
NE-1000 Series of Programmable Syringe Pumps
Firmware Version: V3.919
0 10 20 30 40 50 60 70 80 90
0
10
20
30
40
50
60
Time
I
n
f
u
s
i
o
n
R
a
t
e
“WHAT’S YOUR APPLICATION?”™
WARNING
NOT FOR CLINICAL
USE ON HUMANS
Vista de página 0
1 2 3 4 5 6 ... 53 54

Resumo do Conteúdo

Página 1 - SyringePump.com

Publication #1200-01 Firmware Version: V3.919 08/01/14 SyringePump.com Model: NE-1000 Multi-Phaser™ NE-1000 Series of Programmable Syringe Pum

Página 2 - PUMP RESET:PUMP RESET:

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 5 08/01/14 3. Setup ♦ Place the pump on a stable

Página 3 - Table of Contents

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 6 08/01/14 6. User Interface mm Volume Dispensed

Página 4

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 7 08/01/14 “Volume Dispensed” refers to the volume

Página 5

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 8 08/01/14 6.6 ‘Rate’ and ‘Program Phase #’ Key Wh

Página 6 - General Information

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 9 08/01/14 6.7.2 Clearing “Volume Dispensed” With

Página 7 - Overview

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 10 08/01/14 6.10 ‘Program Phase #’ (Number) Key Whe

Página 8

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 11 08/01/14 6.13.2 Reset Pumping Program To clear

Página 9 - TerminologyTerminology

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 12 08/01/14 n An error was detected during power up

Página 10 - Loading Syringes

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 13 08/01/14 To change the Volume Units, display the

Página 11 - User Interface

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 14 08/01/14 The “Volume Dispensed” accumulations fo

Página 12 - ‘Diameter’ and ‘Setup’ Key

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 i 08/01/14 Quick Start Instructions Assumes that

Página 13 - 6.6.2 Program Entry Mode

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 15 08/01/14 nn RS-232 pump network address, where

Página 14 - ‘Start’/’Stop’ Key

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 16 08/01/14 P2 7 Stop Only Reversed Rising edge

Página 15 - Special Power-Up Functions

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 17 08/01/14 The "Lockout Disable Key" con

Página 16 - Error and Alarm Messages

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 18 08/01/14 Program can interact with external devi

Página 17 - Operation

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 19 08/01/14 9.1.1 Pumping Program Phase Number To

Página 18 - Model NE-1000 Multi-Phaser™

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 20 08/01/14 9.3 Program Function Descriptions 

Página 19 - Setup Configuration

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 21 08/01/14 of production dispenses to be programme

Página 20 - Audible Alarm Enable

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 22 08/01/14 When a ‘loop end’ function is executed,

Página 21 - Keypad Lockout

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 23 08/01/14 After being triggered, the event trigge

Página 22 - Pumping Program

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 24 08/01/14 9.4 Pumping Program Examples 9.4.1 Exa

Página 23

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 ii 08/01/14 Table of Contents 1. GENERAL INFORMA

Página 24

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 25 08/01/14 Phase Function 7 BEEP Phase Function

Página 25

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 26 08/01/14 Phase Function 11 LP:50 Phase Functi

Página 26

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 27 08/01/14 Phase Function 12 LP:03 Phase Functi

Página 27

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 28 08/01/14 Phase Function Rate Volume Directio

Página 28

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 29 08/01/14 Phase Function 6 LP:ST Phase Functio

Página 29 - Pumping Program Examples

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 30 08/01/14 Phase Function Rate Volume Directio

Página 30

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 31 08/01/14 Phase Function Rate Volume Directio

Página 31

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 32 08/01/14 on the next pump in the network. Up to

Página 32

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 33 08/01/14 <float> => <f> [ <flo

Página 33 -     

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 34 08/01/14 Safe mode uses a modified master-slave

Página 34

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 iii 08/01/14 7.5 CHANGING THE PUMPING RATE AND DI

Página 35

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 35 08/01/14 10.2.5 Network Command Burst The Netwo

Página 36 - RS-232 Communications

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 36 08/01/14 All commands are upper case. <comman

Página 37 - RS-232 Protocol:

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 37 08/01/14 PUMPING RATE RAT [ C | I ] [ <float&

Página 38

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 38 08/01/14 Query response: { INF | WDR | STK} Whi

Página 39

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 39 08/01/14 ALARM SETUP AL [ <on-off> ] Set/q

Página 40 - RS-232 Command Set

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 40 08/01/14 ‘Volume’ and Pumping Direction can be c

Página 41

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 41 08/01/14 Note: Once a special communications mo

Página 42

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 42 08/01/14 11. Logic Interface: TTL Input and Out

Página 43

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 43 08/01/14 Pin # Definition Type Function 1 Vc

Página 44

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 44 08/01/14 Stop Only: Falling edge Stops the Pumpi

Página 45 - 10.4.5 System Commands

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 iv 08/01/14 10.2 RS-232 PROTOCOL: ...

Página 46 - Getting Started With RS-232

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 45 08/01/14 12. Appendix 12.1 RS-232 Command Summar

Página 47 - Figure 2: Rear of Pump

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 46 08/01/14 12.2 RS-232 Pump Network Connector Wiri

Página 48 - TTL I/O Operational Controls

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 47 08/01/14 12.3.4 Automation Cable: Special Comm

Página 49 - TTL I/O Control from RS-232

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 48 08/01/14 Pump doesn’t stop after dispensing a se

Página 50 - RS-232 Command Summary

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 49 08/01/14 12.7 Syringe Diameters and Rate Limits

Página 51 - 12.3.2 Syringe Heater

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 1 08/01/14 1. General Information Thank you for p

Página 52 - 12.3.8 Firmware Upgrade

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 2 08/01/14 A return authorization number must be

Página 53 - Custom Applications

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 3 08/01/14 2.1 Glossary of Terminology and Concep

Página 54 - 08/01/14

New Era Pump Systems Inc. www.SyringePump.com Model NE-1000 Multi-Phaser™ Publication #1200-01 4 08/01/14 TerminologyTerminologyTerminologyTermi